Fouling Issue / Frequency |
A steam-heated evaporation system recovers a volatile organic from a heavy organic solution laden with foulants. A hard, black scale that was forming in the upper 25% of the tubes was forcing the plant to switch two parallel once-through rising film evaporators with a clean pair every four to five days. When asked to increase throughput and simplify operations engineers considered installing a 2100-sq-ft falling film evaporator (FFE) to operate in series with the existing rising film evaporators (RFE). Although the combination system was expected to run approximately 10 weeks between cleanings, a better solution was needed. |
|
Solution / Approach |
A fluidized bed heat exchanger used as a re-boiler for an evaporator system to recover a volatile organic (82 m2) |
Process Conditions | Tube | Shell |
---|---|---|
Medium | Proprietary Liquid | Condensing Steam |
Pressure | 5 barg | 11.4 barg |
Temperature | In: 124oC Out: 150oC |
Condensing at 181.5oC |
Flow | 160 m3/h | 788 m3/h |
Dimensions | |
---|---|
Number of Tubes | 55 |
Length of Tubes | 10.5 m |
Diameter Tubes | 47.5 mm |
Particle Type | Stainless Steel |
Particle Size | 2 mm |
Results |
More than 20 years in operation. |